The T9/T10DCS Spectrophotometer incorporates dual monochromator technology making it well suited to even the most demanding of applications in all areas of UV-Visible Spectroscopy.
The optical design of both the T9DCS and T10DCS offer extremely low stray light characteristics (≤0.00004%T NaI,220 nm) which allows for an extensive photometric range (-8.0 – 8.0Abs). Measurements at deep ultra-violet wavelengths can also be achieved with use of Nitrogen purged optics.
Only a few left!
-
Overview
-
Key Features
-
Specifications
-
Downloads
<
>
The T9/T10DCS Spectrophotometer incorporates dual monochromator technology making it well suited to even the most demanding of applications in all areas of UV-Visible Spectroscopy.
The optical design of both the T9DCS and T10DCS offer extremely low stray light characteristics (≤0.00004%T NaI,220 nm) which allows for an extensive photometric range (-8.0 – 8.0Abs). Measurements at deep ultra-violet wavelengths can also be achieved with use of Nitrogen purged optics.
The instrument can be optically configured to suit the needs of the sample by means of a continually adjustable slit for precise control of spectral resolution and beam size adjustment by means of an attenuating wheel.
The optical design of both the T9DCS and T10DCS offer extremely low stray light characteristics (≤0.00004%T NaI,220 nm) which allows for an extensive photometric range (-8.0 – 8.0Abs). Measurements at deep ultra-violet wavelengths can also be achieved with use of Nitrogen purged optics.
The instrument can be optically configured to suit the needs of the sample by means of a continually adjustable slit for precise control of spectral resolution and beam size adjustment by means of an attenuating wheel.
- True Double Beam Double monochromator Optics, and fully sealed to provide ultra-low stray light (0.00004%%T @220nm) and high photometric range (-8.0~8.0 Abs)
- 185– 900nm Wavelength range with Nitrogen purge
- Precise Wavelength accuracy is ensured by the integrated Mercury lamp for automatic correction
- Continuously selectable spectra bandwidth from 0.1-5nm
- Beam size continuously adjustable for variety of applications including ultra-volume cuvettes
- Large sample compartment suitable for all kinds of accessories, especially for 150mm integrating sphere
- Supports Wi-Fi communication in field operation
- The integrated Mercury Emissions Lamp with automatic correction function ensures precise wavelength accuracy
Optical System |
Double beam |
Scan Speed |
1000 nm/min 1500 nm/min location speed |
Wavelength Range |
185-900 nm |
Wavelength Accuracy |
±0.2 nm |
Spectral Bandwidth |
±20 % (0.1 nm-5 nm continuously adjustable) |
Photometric Mode |
Transmittance, Absorbance, Enegy, and Concentration |
Photometric Range |
T9DCS: -6.0 Abs-6.0 Abs T10DCS: -8.0 Abs-8.0 Abs |
Photometric Accuracy |
|
Photometric Reproducibility |
|
Photometric Noise |
0 % Noise: ≤0.01 % 100 % Noise: ≤0.1 % |
Baseline Flatness |
T9DCS: ±0.0008 Abs T10DCS: ±0.0005 Abs |
Baseline Stability |
0.1 %/hr |
Stray light |
T9DCS: ≤0.0001 %T (NaI, 220 nm) ≤0.0001 %T (NaNO2, 360 nm) T10DCS: ≤0.00004 %T (NaI, 220 nm) ≤0.00002 %T (NaNO2, 360 nm) |
Cell Holder |
Automatic 8 Cell Changer |
Detector |
Photo multiplier tube |
Light Source |
D2 lamp,Tungstern lamp,Mercury lamp for WL correction |
PC Interface |
RS232, USB, Wifi |
Software Support |
UV Win |
Power Supply |
Switchable 120-230 VAC 50-60 Hz |
Weight |
136 lb |
Dimensions (W x D x H) |
36 x 25 x 12 in |