Scinteck Instruments
  • Store
  • About Us
  • Contact Us
  • Downloads
  • Store
  • >
  • New
  • >
  • Lamps & Photomultiplier Tubes
  • >
  • Photomultiplier Tubes
  • >
  • Photomultiplier Tube, 160-900 nm Range, Quartz Window

Photomultiplier Tube, 160-900 nm Range, Quartz Window

SKU: 77348
$2,409.25
$2,409.25
Unavailable
per item

The 77348 Photomultiplier Tube covers the 160 to 900 nm range with a peak wavelength of 400 nm, with a Quartz window material. PMTs are the most sensitive single channel detector offered by Oriel Instruments, making them an excellent choice for low-light measurements.

Add to Cart
  • The 77348 Photomultiplier Tube covers the 160 to 900 nm range with a peak wavelength of 400 nm, with a Quartz window material. PMTs are the most sensitive single channel detector offered by Oriel Instruments, making them an excellent choice for low-light measurements.
  • Please note the maximum DC anode currents (averaged over any 30 time interval), and make sure they are not exceeded in your standard set-up. For pulsed applications you can draw up to 50x higher currents for short times, as long as average current ratings are not exceeded.
  • PMTs can be damaged by exposure to excessive light levels in the presence of bias voltage. This is due to anode damage by high current densities. Because the photocathodes of PMTs are very light sensitive, their noise behavior is negatively affected by exposure to strong light, even in the absence of bias voltage, and may take some time to recover once they are screened from light. Typically, more than half an hour is required for recovery. You may need several hours to return to the lowest noise levels. Opening your optical set-up while the PMT is biased can easily lead to a need for an expensive replacement tube.
  • Oriel's Lock-In Digital Amplifier, model LIDA-SRS-KIT, may be used to help separate signals from the background noise.

Specifications

  • Active Area
    8 x 24 mm
  • Wavelength Range
    160-900 nm
  • NEP
    1.3 x 10-16 W
  • Peak Responsivity
    74 mA/W  
  • Rise Time
    2.2 ns  
  • Transit Time
    22 ns  
  • Current
    100 µA  
  • Current Amplification
    1.0 x 107
  • Dark Current
    3 nA  
  • Bias Voltage
    1250 V Absolute Maximum  
  • Anode Responsivity
    7.4 x 105 A/W
  • Peak Wavelength
    400 nm  
  • Operating Temperature Range
    -30 to +50°C

Company

About Us


Support

Contact Us
Terms of Use
© 2021 Scinteck Instruments, LLC. All Rights Reserved
  • Store
  • About Us
  • Contact Us
  • Downloads