Floor Mount Reverse Osmosis System | 2,000 GPD

Reverse Osmosis System always catches your eye with all of its chrome and stainless steel, but its a lot more than a pretty face. Underneath all that chrome and stainless is the heart of a beast! A beast with respect to energy savings, a beast with Energy-Mizer membranes and a beast with incredible longevity.

Features & Benefits

  • Wall Mounted to conserve space
  • 75% to 80% recovery means that this system can waste only 1 gallon for every 4 gallons it makes
  • Ultra Low Energy Miser Membranes Save up to 40% on energy and since they operate at just 80 psi, they promote system longevity.
  • Heavy-Duty Franklin Stainless Steel Centrifugal Pump Unlike lightweight imitators, the Patriot does not use a diaphragm or rotary-vane pump, but rather, a continuous-duty true commercial-grade pump.
  • Stainless-Steel Membrane Housings Never rust and last forever. Easy to change membranes with non-corrosive seals.
  • Includes the following:
    • 5 Micron Magna Pre-Filter with 36 sq/ft of media (usually change yearly)
    • 1 Micron Magna Pre-Filter with 36 sq/ft of media (usually change yearly)
    • Stainless Steel (True Commercial-Grade) Centrifugal Pump
    • (3) 850 - 1,000 GPD Energy-Miser Membranes (Can produce up to 3,000 GPD under the right conditions, but we rate it at 2,000 to be conservative)

    Unparalleled Warranty

    • 3-Year Comprehensive System Warranty (not including consumables)
    • Legendary Technical Support after the sale

    Engineering Specifications

    Design
    ConfigurationSingle Pass
    Feed Water SourceTDS < 2000
    Recovery RateUp to 75%
    Rejection and Flow Rates
    Nominal Salt Rejection %98.5
    Permeate Flow* gpm (lpm)1.38 (5.22)
    Minimum Feed Flow gpm (lpm)2.35 (8.89)
    Maximum Feed Flow gpm (lpm)6.00 (22.70)
    Minimum Concentrate Flow gpm (lpm)1.00 (3.78)
    Connections
    Feed inch1 FNPT
    Permeate inch1 FNPT
    Concentrate inch1 FNPT
    Membranes
    Membranes(s) Per Vessel1
    Membrane Quantity3
    Membrane Size2.5" x 40"
    Vessels
    Vessel Array1:1:1
    Vessel Quantity3
    Pumps
    Pump TypeMulti-Stage
    Motor HP (kw)1.5 (1.12)
    RPM @ 60 (50 Hz)3450 (2900)
    Electrical**
    Voltage220V 60Hz 1 PH
    Voltage Amp Draw8.3
    System Dimensions ***
    L x W x H inch (cm)30 x 38 x 47 (76 x 96 x 119)
    Weight lb. (kg)265 (113)

    *Product Flow rates are based on equipment test parameters.
    **Call for other voltage options.
    ***Does not include operating space requirements.

    Operating Limits
    Maximum Feed Temperature °F (°C)85 (29.00)
    Minimum Feed Temperature °F (°C)40 (4.44)
    Maximum Ambient Temperature °F (°C)120 (48.89)
    Minimum Ambient Temperature °F (°C)40 (4.44)
    Maximum Feed Pressure psi85
    Minimum Feed Pressure psi45
    Maximum Piping Pressure psi150
    Maximum SDI Rating SDI< 3
    Maximum Free Chlorine ppm0
    Maximum TDS ppm2000
    Maximum Hardness gpg0
    Maximum pH (Continuous)11
    Minimum pH (Continuous)5
    Maximum pH (Cleaning 30 min)12
    Minimum pH (Cleaning 30 min)2
    Maximum Turbidity NTU1

    Test Parameters: *550 TDS Filtered (5 Micron), De-Chlorinated, Municipal Feed Water, 65 psi (4.50 bar) Feed Pressure, 100 psi (6.89 bar) Operating Pressure, 77 Degrees F (25 Degrees C), Recovery as stated, 7.0 pH. Data taken after 60 minutes of operation. Scale prevention measures must be taken to prolong membrane life.

    Low temperatures and high feed water TDS levels will significantly affect system's production capabilities. Computer projections should be run for individual applications which do not meet or exceed minimum and maximum operating limits.

    NOTE: US Water rates their reverse osmosis systems under industry standards which are tested at 77 degree F, 500 TDS and 60 psi pressure. Production can vary dramatically depending upon water pressure, temperature and TDS (total dissolved solids) levels. US Water does not make these standards - we just adhere to the industry standards when testing and report what the standards require. Every manufacturer uses these standards.

    *Product Flow rates are based on equipment test parameters.
    **Call for other voltage options.
    ***Does not include operating space requirements.