TL2300 Series Turbidimeter
SKU:
$4,461.17
65
6892.72
$65.00 - $6,892.72
Unavailable
per item
What's included:
TL2300 Turbidimeter, silicone oil, oiling cloth, USEPA filter assembly, 1-inch sample cells (30 mL) with caps (6x), Gelex secondary turbidity standardization kit, Stablcal calibration kit, power supply, power cord, dust cover
Lead Time: 2-4 weeks
Basic User Manual
(Multi-Language)
-
Overview
-
What's in the Box?
-
Specifications
-
Downloads
<
>
The new TL23 Series laboratory turbidimeters blend trusted technology and improved features to simplify testing in the most demanding industrial and wastewater applications.
Hach’s new TL23 lab turbidimeter brings a new face to the trusted legacy 2100N and 2100AN turbidimeters. It utilizes the same optic bloc while delivering an improved user experience with its intuitive interface, which ties perfectly to the rest of Hach’s laboratory instruments.
Having the same optic bloc means that you can replace your old 2100N/AN with a TL23 turbidity meter without having to change any of your standard operating procedures.
Hach’s new TL23 lab turbidimeter brings a new face to the trusted legacy 2100N and 2100AN turbidimeters. It utilizes the same optic bloc while delivering an improved user experience with its intuitive interface, which ties perfectly to the rest of Hach’s laboratory instruments.
Having the same optic bloc means that you can replace your old 2100N/AN with a TL23 turbidity meter without having to change any of your standard operating procedures.
Improved and intuitive design
The TL23 Series’ large full color touch screen display and intuitive user interface accelerate setup, calibration and measurement. An easy interface and guided procedures give you confidence in your results.
A smart device for more reliable measurements
The TL23 Series ensures stable readings and accurate analysis by capturing turbidity readings once the device detects sample stability. This quality step removes subjectivity and the need for repeated measurements.
Easy to use. Easy to Be Right
The TL23 Series provides everything you need at your fingertips. With a USB port for easy data export, sample identification for traceability, and self-diagnostics for quality assurance, Hach® makes it easy to Be Right.
- TL2300 Turbidimeter, silicone oil
- Oiling cloth
- USEPA filter assembly
- 1-inch sample cells (30 mL) with caps (6x)
- Gelex secondary turbidity standardization kit
- Stablcal calibration kit
- Power supply
- Power cord
- Dust cover
Accuracy |
Ratio on: ±2% of reading plus 0.01 NTU from 0 - 1000 NTU, ±5% of reading from 1000 - 4000 NTU based on formazin primary standard Ratio off: ±2% of reading plus 0.01 NTU from 0 - 40 NTU |
Air Purge |
Dry nitrogen or instrument grade air (ANSI MC 11.1, 1975) 0.1 scfm at 69 kPa (10 psig); 138 kPa (20 psig) max Hose barb connection for 1/8-inch tubing |
Certifications |
CE, KC, RCM |
Communication |
USB |
Data Logging |
2000 total logs, includes reading log, verification log and calibration log |
Dimensions (H x W x D) |
153 mm x 395 mm x 305 mm |
Display |
17.8 mm (7 in.) color touch screen |
Interface |
2 USB-A ports for USB flash drive, external thermal printer, keyboard and barcode scanner |
Light Source |
Tungsten filament lamp |
Measurement Method |
Nephelometric |
Model |
TL2300 EPA |
Operating Temperature Range |
0 - 40 °C |
Power Requirements (Amps) |
3.4 A |
Power Requirements (Hz) |
50/60 Hz |
Power Requirements (Voltage) |
100 - 240 VAC |
Range |
NTU (Ratio on): 0 - 4000 NTU (Ratio off): 0 - 40 EBC (Ratio on): 0 - 980 EBC (Ratio off): 0 - 9.8 |
Reading Modes |
Single, continuous, Rapidly Settling Turbidity™, signal averaging on or off, ratio on or off |
Regulatory |
Meets EPA Method 180.1 |
Repeatability |
±1% of reading or 0.01 NTU, whichever is greater (under reference conditions) |
Response Time |
Signal averaging off: 6.8 seconds / Signal averaging on: 14 seconds (when 10 measurements are used to calculate the average) |
Sample Cell Compatibility |
Round cells 95 x 25 mm (3.74 x 1 in.) borosilicate glass with rubber-lined screw caps Note: Smaller sample cells (less than 25 mm) can be used when a cell adapter is used. |
Sample Requirements |
25 mm sample cell: 20 mL minimum 0 to 70 °C (32 to 158 °F) |
Stabilization Time |
Ratio on: 30 minutes after start-up Ratio off: 60 minutes after start-up |
Storage Conditions |
-20 to 60 °C |
Units |
NTU and EBC |
Weight |
5.0 kg |
Basic User Manual (Multi-Language) |
User Manual
|
TL23 Software Package |
|