- Store
- >
- New
- >
- pH/Conductivity/Ion/DO Meters
- >
- Electrodes & Probes
- >
- pH Electrodes & Probes
- >
- LabSen 831 Refillable pH Electrode for HF (Hydrofluoric) Acid Containing Solutions and Strong Acidic Solutions, BNC Connector
LabSen 831 Refillable pH Electrode for HF (Hydrofluoric) Acid Containing Solutions and Strong Acidic Solutions, BNC Connector
SKU:
AI3109
$143.10
$143.10
Unavailable
per item
Built with proprietary sensor technology and premium materials from Switzerland, Apera LabSen 831 HF pH Electrode is designed for professional pH measurement of solutions containing HF (Hydrofluoric) acid, and other strong acidic solutions.
LabSen HF glass membrane –– designed for accurate measurement in strong acid samples, and is resistant to hydrofluoric corrosion, good for 1000 times of measurement (measurement time<1 minute, and HF concentration must be less than 0.1mol/L or 2000 ppm)
Built tough –– The hemispherical glass membrane is 10 times stronger than traditional glass membranes, and highly resistant to general impact, saving the electrode from accidental damage.
Silver Ion Trap Reference System –– On top of the Long-Life reference system, a silver ion trap is added to further prevent junction clogs.
The electrode uses a BNC connector, compatible with any pH meters that use BNC connectors. No temperature sensor is built-in. Users need to have a separate temperature probe (ex: Apera MP500) to enable ATC or manually input temperature to realize temperature compensation.
LabSen HF glass membrane –– designed for accurate measurement in strong acid samples, and is resistant to hydrofluoric corrosion, good for 1000 times of measurement (measurement time<1 minute, and HF concentration must be less than 0.1mol/L or 2000 ppm)
Built tough –– The hemispherical glass membrane is 10 times stronger than traditional glass membranes, and highly resistant to general impact, saving the electrode from accidental damage.
Silver Ion Trap Reference System –– On top of the Long-Life reference system, a silver ion trap is added to further prevent junction clogs.
The electrode uses a BNC connector, compatible with any pH meters that use BNC connectors. No temperature sensor is built-in. Users need to have a separate temperature probe (ex: Apera MP500) to enable ATC or manually input temperature to realize temperature compensation.
Features
|
SpecificationspH Range: 0-12 pH
Temp. Range: 0 to 100°C (32 to 212°F) Housing Material: Lead-free glass Temp. Sensor: No Junction: Ceramic Reference: Silver Ion Trap Electrolyte: 3M KCL Length: 120mm Diameter: 12mm Membrane Shape: Hemispherical Membrane Impedance: <400MΩ Connector: BNC Cable: 3 Ft |