HI904 Coulometric Karl Fischer Titrator
SKU:
$6,450.00
$5,750.00
$5,750.00
Unavailable
per item
For scientists and professionals who need precise water content determination from 1 ppm to 5%, the HI904 is a reliable Coulometric Karl Fischer titrator that gives results in minutes.
Unlike volumetric Karl Fischer titrators, the HI904 features an precision titrant generation system and a fully sealed titration vessel for unmatched accuracy.
Product Description
The Hanna HI 904 Karl Fischer Coulometric Titrator for moisture analysis measures 1 ppm to 5% water content.
The HI904 combines an ultra-high electrolytically generated iodine dynamic dosing system with optically-regulated magnetic
stirring, sophisticated endpoint determination, and background drift correction algorithms. The result is an extremely adaptable titrator capable of titrating with superior accuracy and precision for samples with low moisture content. The HI904 applies a pulsed DC current for titrant generation, detects the endpoint and performs all necessary calculations automatically.
The HI904 comes equipped with a solvent handling system to reduce cell conditioning time and can be connected directly to a laboratory analytical balance via RS232 serial interface. The HI904's powerful software and intuitive menus are easily navigated on the large, color LCD display, making it simple to view results. Choose from included methods or develop a custom method for almost any application or sample type. Methods (standard or user) and reports can be transferred between titrator and PC via USB interface by using the Hanna
PC software. Software updates can be performed using a USB flash drive.
Frit-less (no diaphragm) generator electrode - uses one easy-to-replace Karl Fischer reagent because the anode and cathode reactions take place in the same electrolyte
lower and more stable drift rates
easier cleaning of generator cell
no contamination of a diaphragm
good for hydrocarbons, alcohols, esters, ketones and oils
Precision dosing system by generator electrode
400 mA pulsed current
Fritless (No Diaphragm) Generator uses one easy-to-replace Karl Fischer reagent and has a lower and more stable drift rate. Offers easier cleaning of generator cell.
Molecular sieve desiccant
Prevents the ingress of ambient humidity into the sealed solvent system while maintaining full titrator functionality
Regenerated at 300°C
Sealed cell:
Generator electrode
Dual pin bi-voltammetric platinum sensing electrode
Molecular sieve desiccant cartridge
Replaceable septum for liquid sampling port
Accessory port
Built-in stirrer
Automatic, integrated magnetic stirrer adjustable from 200-2000 RPM-
Optical feedback for automatic speed control
Sealed solvent system
Change to fresh reagent in a matter of seconds without opening titration vessel
Minimizes exposure to ambient humidity
PTFE tubing is resistant to harsh KF chemicals
Sealed tube holder to collect PTFE tube after exchanging reagent
PTFE bottle cap
Caps fit any GL45-threaded bottle
Chemically-resistant caps and fittings
Removable desiccant cartridges
Supports up to 100 methods (standard and user-defined)
Results displayed directly in the selected units
Titration graph can be displayed on-screen and saved as an image to be transferred to a PC or printed
USB flash drive input: Transfer methods, reports and graphs to a PC or other titration system; Field upgradable software
Incorporates into any GLP data management program: Easily record all necessary GLP information with every sample, including company and operator name, date, time, electrode ID codes and standardization information
Proper mixing of reagent and sample: Digital, magnetic stirring system with optical feedback; Adjustable stirring speed to facilitate mixing
Flexible, accurate detection of the titration endpoint: Dual, platinum pin polarization electrode for bivoltammetric detection of endpoint
Multi-language support
Balance interface: Automatically acquire sample mass via RS232 serial interface
Easy to operate: User-friendly interface and Contextual help screens
VERSATILE DATA MANAGEMENT:
HI900 Series titration systems can be easily incorporated into any existing GLP data management program: Easily record all necessary GLP information with every sample, such as sample identification, company and operator name, date, time, electrode ID codes and calibration information
Data can be transferred to a PC using Hanna HI900PC software
The USB port allows for the easy transfer of methods, reports and software upgrades via a USB flash drive
Users can print reports of analyses directly from the titrator using a standard parallel printer
An external monitor and keyboard can be attached for added versatility
The Hanna HI 904 Karl Fischer Coulometric Titrator for moisture analysis measures 1 ppm to 5% water content.
The HI904 combines an ultra-high electrolytically generated iodine dynamic dosing system with optically-regulated magnetic
stirring, sophisticated endpoint determination, and background drift correction algorithms. The result is an extremely adaptable titrator capable of titrating with superior accuracy and precision for samples with low moisture content. The HI904 applies a pulsed DC current for titrant generation, detects the endpoint and performs all necessary calculations automatically.
The HI904 comes equipped with a solvent handling system to reduce cell conditioning time and can be connected directly to a laboratory analytical balance via RS232 serial interface. The HI904's powerful software and intuitive menus are easily navigated on the large, color LCD display, making it simple to view results. Choose from included methods or develop a custom method for almost any application or sample type. Methods (standard or user) and reports can be transferred between titrator and PC via USB interface by using the Hanna
PC software. Software updates can be performed using a USB flash drive.
Frit-less (no diaphragm) generator electrode - uses one easy-to-replace Karl Fischer reagent because the anode and cathode reactions take place in the same electrolyte
lower and more stable drift rates
easier cleaning of generator cell
no contamination of a diaphragm
good for hydrocarbons, alcohols, esters, ketones and oils
Precision dosing system by generator electrode
400 mA pulsed current
Fritless (No Diaphragm) Generator uses one easy-to-replace Karl Fischer reagent and has a lower and more stable drift rate. Offers easier cleaning of generator cell.
Molecular sieve desiccant
Prevents the ingress of ambient humidity into the sealed solvent system while maintaining full titrator functionality
Regenerated at 300°C
Sealed cell:
Generator electrode
Dual pin bi-voltammetric platinum sensing electrode
Molecular sieve desiccant cartridge
Replaceable septum for liquid sampling port
Accessory port
Built-in stirrer
Automatic, integrated magnetic stirrer adjustable from 200-2000 RPM-
Optical feedback for automatic speed control
Sealed solvent system
Change to fresh reagent in a matter of seconds without opening titration vessel
Minimizes exposure to ambient humidity
PTFE tubing is resistant to harsh KF chemicals
Sealed tube holder to collect PTFE tube after exchanging reagent
PTFE bottle cap
Caps fit any GL45-threaded bottle
Chemically-resistant caps and fittings
Removable desiccant cartridges
Supports up to 100 methods (standard and user-defined)
Results displayed directly in the selected units
Titration graph can be displayed on-screen and saved as an image to be transferred to a PC or printed
USB flash drive input: Transfer methods, reports and graphs to a PC or other titration system; Field upgradable software
Incorporates into any GLP data management program: Easily record all necessary GLP information with every sample, including company and operator name, date, time, electrode ID codes and standardization information
Proper mixing of reagent and sample: Digital, magnetic stirring system with optical feedback; Adjustable stirring speed to facilitate mixing
Flexible, accurate detection of the titration endpoint: Dual, platinum pin polarization electrode for bivoltammetric detection of endpoint
Multi-language support
Balance interface: Automatically acquire sample mass via RS232 serial interface
Easy to operate: User-friendly interface and Contextual help screens
VERSATILE DATA MANAGEMENT:
HI900 Series titration systems can be easily incorporated into any existing GLP data management program: Easily record all necessary GLP information with every sample, such as sample identification, company and operator name, date, time, electrode ID codes and calibration information
Data can be transferred to a PC using Hanna HI900PC software
The USB port allows for the easy transfer of methods, reports and software upgrades via a USB flash drive
Users can print reports of analyses directly from the titrator using a standard parallel printer
An external monitor and keyboard can be attached for added versatility
Titration Specifications
Range | 1 ppm to 5% |
---|---|
Resolution | 0.1ppm to 0.0001% |
Result Units | %, ppm, ppt, mg/g, μg/g, mg, μg, mg/mL, μg/mL, mg Br/100g, g Br/100g, mg Br, g Br |
Sample Types | liquid or solid with external dissolution / extraction |
Pre-Titration Conditioning | automatic |
Background Drift Correction | automatic or user-selectable value |
Endpoint Criteria | fixed mV persistence, relative drift stop or absolute drift stop |
Dosing | dynamic |
Result Statistic | mean, standard deviation |
Dosing System Specifications
Generator Configuration | diaphragm or diaphragm-less |
---|---|
Generator Current Control | automatic or fixed (400 mA) |
Generator Type Detection | automatic |
Titration Vessel | operating volume between 100 – 200 mL |
Solvent Handling System | sealed system with integrated diaphragm air pump and beaker adapter |
Sensor System Specifications
Sensor Type | HI76330 dual platinum pin polarization electrode |
---|---|
Sensor Connection | BNC |
Polarization Current | 1, 2, 5, or 10 μA |
Voltage Range | 2 mV to 1100 mV |
Voltage Resolution | 0.1 mV |
Accuracy (@25ºC/77ºF) | ±0.1% |
Additional Specifications
Programmable Stirrer | magnetic, optically regulated, digital stirrer; 200 to 2000 rpm; resolution 100 rpm |
---|---|
Display | 5.7” (320 x 240 pixel) backlit color LCD |
Methods | up to 100 (standard and user) methods |
Logging Data | up to 100 complete titration reports and drift rate reports can be stored |
Peripherals (Rear) | connections for VGA display, PC-keyboard, parallel printer, USB device input, RS232 |
GLP Conformity | Good Laboratory Practice and instrument data storage and printing |
Languages | English, Portuguese. Spanish, and French |
Enclosure Material | ABS plastic and steel |
Keypad | polycarbonate |
Operating Environment | 10 to 40°C (50 to 104°F), up to 95% RH |
Storage Environment | -20 to 70°C (-4 to 158°F), up to 95% RH |
Dimensions | 390 x 350 x 380 mm (15.3 x 13.8 x 14.9”) |