- Store
- >
- New
- >
- Titrators / KF Titrators / KF Potentiometer
- >
- Hanna Instruments
- >
- Volumetric Karl Fischer Titrators
- >
- HI903-01 Volumetric Karl Fischer Titrator
HI903-01 Volumetric Karl Fischer Titrator
SKU:
$5,250.00
$4,750.00
$4,750.00
Unavailable
per item
For scientists and professionals who need exact water content determination from 0.01 to 100%, the HI903 is a reliable Volumetric Karl Fischer Titrator that gives results in minutes.
2 available
HI903-01 Volumetric Karl Fischer Titrator
Unlike other Karl Fischer titrators, the HI903 features an ultra-high precision dosing system and a specialized burette design for unmatched accuracy.
A Better Volumetric Karl Fischer Titrator Experience Our friendly technical consultants take pride in helping make your titrator selection easy – every step of the way. Our experts are here to guarantee you have a positive experience, from onsite installation and training to customization and continued support.
The HI 903 Karl Fischer Volumetric Titrator for moisture analysis combines an ultra-high precision titrant delivery system with optically regulated magnetic stirring, sophisticated endpoint determination, dynamic dosing and background drift correction algorithms. The HI 903 dispenses the titrant, detects the endpoint and performs all necessary calculations
automatically. It comes equipped with a solvent handling system to reduce cell conditioning time and can be connected directly to your laboratory balance via serial interface.
- Data can be transferred to a PC using the HANNA HI 900PC software application
- The USB port allows for the easy transfer of methods, reports and software upgrades via a USB flash drive
- Users can print reports of analyses directly from the titrator using a standard parallel printer
- An external monitor and keyboard can be attached for added versatility
Beaker top
- Chemically-resistant reaction vessel cap and fittings
- Quick-remove sample port plug with replaceable silicone rubber septum
Anti-diffusion burette tip
- Delivers titrant in high turbulence zone, ensuring rapid reaction
- Prevents unwanted diffusion of titrant
Built-in stirrer
- Automatic, integrated magnetic stirrer adjustable from 200-2000 RPM
- Optical feedback for automatic speed control
- Optional external stirrer available
Rechargeable indicating desiccant
- Prevents the ingress of ambient humidity into the sealed solvent system while maintaining full titrator functionality
- Minimizes changes to titrant titre
- Indicates when adsorption capacity is depleted
- Regenerates at 150°C
PTFE bottle cap
- Caps fit any GL45-threaded bottle
- Chemically resistant caps and fittings
- Removable desiccant cartridges
Large 5.7" (320 x 240 pixel) color LCD with backlight
Titrant database
- Stores standardization information for up to 20 titrants
- Standardization reminders
Supports up to 100 titration methods (standard and user defined)
Dynamic dosing with optional pre-dispensing
Results displayed directly in the selected units
Titration graph can be displayed on-screen and saved as a bitmap
Multi language support
USB flash drive input
- Transfer methods, reports and graphs to either a PC or other titration system
- Field-upgradeable software
Incorporates into any GLP data management program:
- Easily record all necessary GLP information with every sample including company and operator name, date, time, electrode ID codes and calibration information
Compatible with most major titrant and solvent brands
Proper mixing of titrant and analyte
- Digital, magnetic stirring system with optical feedback
- Conical titration cell to facilitate mixing over a wide volume range
- Upward dispensing of titrant to ensure rapid reaction
Flexible, accurate detection of the titration endpoint
- Dual platinum pin polarization electrode for bivoltametric indication
- Signal averaging reduces noise
- Selectable endpoint criteria: fixed mV persistence, relative drift stop or absolute drift stop
Balance interface
- Automatically acquire sample mass or volume via serial RS-232 interface
Easy to operate
- User friendly interface
- Context-sensitive help screens
- Self diagnostic features for external components including dosing pump, burette and stirrer
Ideal for food and beverage, pharmaceuticals, cosmetics, chemical and petrochemical manufacturing and solvents
The following link provides additional information from the instruction manual or original manufacturer's brochure. Right-click to open the PDF in a new window or
A Better Volumetric Karl Fischer Titrator Experience Our friendly technical consultants take pride in helping make your titrator selection easy – every step of the way. Our experts are here to guarantee you have a positive experience, from onsite installation and training to customization and continued support.
The HI 903 Karl Fischer Volumetric Titrator for moisture analysis combines an ultra-high precision titrant delivery system with optically regulated magnetic stirring, sophisticated endpoint determination, dynamic dosing and background drift correction algorithms. The HI 903 dispenses the titrant, detects the endpoint and performs all necessary calculations
automatically. It comes equipped with a solvent handling system to reduce cell conditioning time and can be connected directly to your laboratory balance via serial interface.
- Data can be transferred to a PC using the HANNA HI 900PC software application
- The USB port allows for the easy transfer of methods, reports and software upgrades via a USB flash drive
- Users can print reports of analyses directly from the titrator using a standard parallel printer
- An external monitor and keyboard can be attached for added versatility
Beaker top
- Chemically-resistant reaction vessel cap and fittings
- Quick-remove sample port plug with replaceable silicone rubber septum
Anti-diffusion burette tip
- Delivers titrant in high turbulence zone, ensuring rapid reaction
- Prevents unwanted diffusion of titrant
Built-in stirrer
- Automatic, integrated magnetic stirrer adjustable from 200-2000 RPM
- Optical feedback for automatic speed control
- Optional external stirrer available
Rechargeable indicating desiccant
- Prevents the ingress of ambient humidity into the sealed solvent system while maintaining full titrator functionality
- Minimizes changes to titrant titre
- Indicates when adsorption capacity is depleted
- Regenerates at 150°C
PTFE bottle cap
- Caps fit any GL45-threaded bottle
- Chemically resistant caps and fittings
- Removable desiccant cartridges
Large 5.7" (320 x 240 pixel) color LCD with backlight
Titrant database
- Stores standardization information for up to 20 titrants
- Standardization reminders
Supports up to 100 titration methods (standard and user defined)
Dynamic dosing with optional pre-dispensing
Results displayed directly in the selected units
Titration graph can be displayed on-screen and saved as a bitmap
Multi language support
USB flash drive input
- Transfer methods, reports and graphs to either a PC or other titration system
- Field-upgradeable software
Incorporates into any GLP data management program:
- Easily record all necessary GLP information with every sample including company and operator name, date, time, electrode ID codes and calibration information
Compatible with most major titrant and solvent brands
Proper mixing of titrant and analyte
- Digital, magnetic stirring system with optical feedback
- Conical titration cell to facilitate mixing over a wide volume range
- Upward dispensing of titrant to ensure rapid reaction
Flexible, accurate detection of the titration endpoint
- Dual platinum pin polarization electrode for bivoltametric indication
- Signal averaging reduces noise
- Selectable endpoint criteria: fixed mV persistence, relative drift stop or absolute drift stop
Balance interface
- Automatically acquire sample mass or volume via serial RS-232 interface
Easy to operate
- User friendly interface
- Context-sensitive help screens
- Self diagnostic features for external components including dosing pump, burette and stirrer
Ideal for food and beverage, pharmaceuticals, cosmetics, chemical and petrochemical manufacturing and solvents
The following link provides additional information from the instruction manual or original manufacturer's brochure. Right-click to open the PDF in a new window or
Titration Specifications
Range | 100 ppm to 100% |
---|---|
Resolution | 1 ppm to 0.0001% |
Result Units | %, ppm, mg/g, μg/g, mg, μg, mg/mL, μg/mL, mg/pc, μg/pc |
Sample Types | liquid or solid |
Pre-Titration Conditioning | automatic |
Background Drift Correction | automatic or user-selectable value |
Endpoint Criteria | fixed mV persistence, relative drift stop or absolute drift stop |
Dosing | dynamic with optional pre-dispensing rate |
Result Statistic | mean, standard deviation |
Dosing System Specifications
Dosing Pump Resolution | 1/40000 of the burette volume (0.125 μL per dose) with 5 mL burette |
---|---|
Dosing Pump Accuracy | ±0.1% of full burette volume |
Syringe | 5 mL precision ground glass with PTFE plunger |
Valve | motor-driven 3-way, PTFE liquid contact material |
Tubing | PTFE with light block and thermal jacketing |
Dispensing Tip | glass, fixed position, anti-diffusing |
Titration Vessel | conical with operation volume between 50-150 mL |
Solvent Handling System | sealed system, integrated diaphragm air pump |
Sensor System Specifications
Sensor Type | HI76320 dual platinum pin polarization electrode |
---|---|
Sensor Connection | BNC |
Polarization Current | 1, 2, 5, 10, 15, 20, 30 or 40 μA |
Voltage Range | 2 mV to 1000 mV |
Voltage Resolution | 0.1 mV |
Accuracy (@25ºC/77ºF) | ±0.1% |
Additional Specifications
Programmable Stirrer | magnetic, optically regulated, digital stirrer; 200 to 2000 rpm; resolution 100 rpm |
---|---|
Display | 5.7” (320 x 240 pixel) color LCD |
Methods | up to 100 methods (standard and user-defined) |
Logging Data | up to 100 complete titration reports and drift rate reports can be stored |
Peripherals (Rear) | connections for VGA display, PC-keyboard, parallel printer, USB device input, RS232 |
GLP Conformity | Good Laboratory Practice and instrument data storage and printing |
Languages | English, Portuguese. Spanish, and French |
Enclosure Material | ABS plastic and steel |
Keypad | polycarbonate |
Operating Environment | 10 to 40°C (50 to 104°F), up to 95% RH |
Storage Environment | -20 to 70°C (-4 to 158°F), up to 95% RH |
Power Supply | 100-240 VAC; "-01" models, US plug (type A); "-02" models, European plug (type C) |
Dimensions | 390 x 350 x 380 mm (15.3 x 13.8 x 14.9 in) |
Weight | approximately 10 kg (22 lbs.) |