- Store
- >
- New
- >
- Rheometers & Viscometers
- >
- Anton Paar
- >
- Anton Paar Rotational Viscometer ViscoQC 100
Anton Paar Rotational Viscometer ViscoQC 100
SKU:
$4,650.00
$4,650.00
Unavailable
per item
The Game Changer
-
Key Features
-
Technical Specifications
<
>
Gets ready immediately and right out of the box
- Already assembled when delivered: Unpack and measure right away
- Choose your national language during the first boot-up of ViscoQC 100
- Correct instrument and Peltier device alignment is ensured digitally at boot-up/measurement
- Relative spindles (L, RH) according to ISO 2555 included in standard delivery
- Store up to 7 spindles in the optional spindle rack to keep your workspace tidy
Quick and easy measurement setup for full traceability of results
- Easy exchange of spindle on ViscoQC 100 using magnetic coupling
- Automatic spindle recognition for error-free measurements using Toolmaster™
- Perfect traceability by automatic detection of attached L or R guard
- Peltier temperature control with air counter-cooling for accurate sample temperature control (+15 °C to +80 °C)
- Monitor your sample temperature with a Pt100 sensor (-60 °C to +300 °C)
- Wide speed range (0.1 rpm to 200 rpm) with customizable speed list
- A flexible cup holder ensures your sample container is always centered at the right place
Most intuitive viscosity quality control measurements for exceptional results
- Unique TruMode™ (auto speed function) finds the right spindle/speed combination for unknown samples
- Reduced waiting time with Peltier temperature device as the T-Ready™ feature automatically signals sample temperature equilibration
- User calibration: Spindle correction factor storable on Toolmaster™
- Intuitive user interface on 3.5” color LCD display with predefined modes
- Predefined modes: Manual Mode, TruMode, Stop at Time/Torque/Temperature
- Prolonged spindle lifetime thanks to high chemical resistance of stainless steel AISI 316L
- Increase sample throughput using disposable aluminum cups (D18)
Fast export of viscosity results and pharma compliance ensured
- Non-storage instrument: direct printout of your results right after measurement
- Easily print labels with the optional DYMO® LabelWriter™
- Free V-Collect data collection software included in every standard deliver
- Don’t worry, be compliant: Instrument qualification
- Available with Pharma Qualification Package – Smart
- Fulfills requirements of GMP, GAMP 5 (except 21 CFR Part 11)
- Install, qualify, and start using ViscoQC 100 within one day
Worldwide support for your viscometer guaranteed – at any time
- Benefit from our exclusive extended three-year warranty program
- At-site exchangeable sensor for minimum downtime in case of repair
- Avoid manual wind-up procedure thanks to automatic bearing check by TruSine™
- A free installation and operational qualification document is included in every delivery
- Fast support ensured by Anton Paar's LiveChat
Viscosity Test |
Single point |
Viscosity range [mPa.s] (depends on the measuring system) |
L - 1* to 6M R - 10** to 40M H*** to 320M |
Speed [rpm] |
0.1 to 200 25 increments: 19 standard speeds plus 6 freely selectable speeds |
Max. spring torque [mNm] |
L - 0.0673 R - 0.7187 H - 5.7496 |
Accuracy |
±1.0 % full scale range |
Repeatability |
±0.2 % |
* With optional double-gap system DG26, with L1 spindle 15 mPa.s
** With optional double-gap system DG26, with RH1 spindle 100 mPa.s
*** With optional double-gap system DG26, with RH1 spindle 800 mPa.s
M=1 million
** With optional double-gap system DG26, with RH1 spindle 100 mPa.s
*** With optional double-gap system DG26, with RH1 spindle 800 mPa.s
M=1 million
-
L Model
-
R Model
-
H Model
<
>
Viscosity Ranges per Torque Model
Min. and max. viscosity are calculated values for L standard speeds (0.3 rpm to 60 rpm).
Spindle |
Min. viscosity [mPa.s] |
Max. viscosity [mPa.s] |
L1 |
15 |
20,000 |
L2 |
50 |
100,000 |
L3 |
200 |
400,000 |
L4 |
1,000 |
2,000,000 |
CC12 |
20 |
37,900 |
CC18 |
5 |
11,400 |
CC26 |
2 |
3,800 |
DG26 |
1 |
2,600 |
CC12/D18 |
70 |
100,000 |
SC4-18 |
5 |
10,000 |
SC4-21 |
10 |
15,500 |
SC4-27 |
40 |
78,000 |
Vane Spindles
Min. and max. viscosity are calculated values at 10 rpm.
Spindle |
Min. viscosity [mPa.s] |
Max. viscosity [mPa.s] |
V71 |
Not Recommended |
Not Recommended |
V72 |
104 |
1,040 |
V73 |
500 |
5,000 |
V74 |
5,090 |
50,900 |
V75 |
1,996 |
19,960 |
Viscosity ranges per torque model
Min. and max. viscosity are calculated values for RH standard speeds (0.5 rpm to 100 rpm, 0.3 rpm as min. for SC4-XY).
Spindle |
Min. viscosity [mPa.s] |
Max. viscosity [mPa.s] |
RH1 |
100 |
20,000 |
RH2 |
100 |
80,000 |
RH3 |
100 |
200,000 |
RH4 |
200 |
400,000 |
RH5 |
400 |
800,000 |
RH6 |
1,000 |
2,000,000 |
RH7 |
4,000 |
8,000,000 |
CC12 |
120 |
50,000 |
CC18 |
40 |
50,000 |
CC26 |
15 |
24,400 |
DG26 |
10 |
10,000 |
CC12/D18 |
440 |
100,000 |
SC4-18 |
30 |
100,000 |
SC4-21 |
50 |
100,000 |
SC4-27 |
250 |
200,000 |
Vane Spindles
Min. and max. viscosity are calculated values at 10 rpm.
Spindle |
Min. viscosity [mPa.s] |
Max. viscosity [mPa.s] |
V71 |
262 |
2,620 |
V72 |
1,110 |
11,100 |
V73 |
5,330 |
53,300 |
V74 |
54,300 |
543,000 |
V75 |
21,300 |
213,000 |
Viscosity ranges per torque model
Min. and max. viscosity are calculated values for RH standard speeds (0.5 rpm to 100 rpm, 0.3 rpm as min. for SC4-XY).
Spindle |
Min. viscosity [mPa.s] |
Max. viscosity [mPa.s] |
RH1 |
800 |
160,000 |
RH2 |
800 |
640,000 |
RH3 |
800 |
1,600,000 |
RH4 |
1,600 |
3,200,000 |
RH5 |
3,200 |
6,400,000 |
RH6 |
8,000 |
16,000,000 |
RH7 |
32,000 |
64,000,000 |
CC12 |
1,000 |
50,000 |
CC18 |
300 |
50,000 |
CC26 |
100 |
50,000 |
DG26 |
60 |
10,000 |
CC12/D18 |
3,500 |
100,000 |
SC4-18 |
250 |
50,000 |
SC4-21 |
400 |
100,000 |
SC4-27 |
2,000 |
200,000 |
Vane Spindles
Min. and max. viscosity are calculated values at 10 rpm.
Spindle |
Min. viscosity [mPa.s] |
Max. viscosity [mPa.s] |
V71 |
2,096 |
20,960 |
V72 |
8,880 |
88,800 |
V73 |
42,640 |
426,400 |
V74 |
434,400 |
4,344,000 |
V75 |
170,400 |
1,704,000 |